Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 2.0 Making the Right Connection
.
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Figure 6: Modem Cable Pin Definitions
(Male DB9 on receiver)
1 - Data carrier detect (DCD)
2 - Receive (RX)
3 - Transmit (TX)
4 - Data terminal ready (DTR)
5 - Signal-ground (SIG-GND)
6 - Data set ready (DSR)
7 - Ready to send (RTS)
8 - Clear to send (CTS)
9 - Ring indicator (RI)
2.2 Selecting Program Options in the D6600/D6100IPv6/D6100i
Use the D6600/D6100IPv6/D6100i keypad or the D6200 Programming Software to program the
receivers. Below are the recommended selections for programming when connecting the receivers to
an automation system. Additional selections can be found in the D6600/D6100IPv6/D6100i Program
Entry Guide (P/N: 4998122702).
Table 1: Recommended Programming Selections
Receiver
Gateway
Number
Selects a number (01 to 99) that is included in every message to the computer in
both D6500 and SIA modes
Output
Format
Enable computer output messages in the selected format:
SIA computer interface standard format, recommended (expanded
reporting capabilities)
D6500 21-character format output
Baud Rate Use maximum speed supported by PC
Link Test Tests if a supervision signal can be sent and received from the central station by
the receiver