Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output
.
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
143
Appendix E: Pulse Output
Table 103 to Table 111 vary depending on the account number specified and the digit
parameter programmed using the drop
-down menus in Menu Item 3.1.7 Event 3/1 or 4/1
(
Figure 27).
The output of the receiver depends on the reporting digit. Use the settings in Figure 27 that can be
changed by the user:
Reporting digits 0 to 9 and A are alarms
Reporting digit B is an opening
Reporting digit C is a closing
Reporting digit D is a cancel
Reporting digit E is a restore
Figure 27: D6200 Receiver Software Line Card Configuration
Table 103: Pulse 3/1 Format
# Event Account
Number
Reporting
Digit
Device/Mode Displays
1.
ALARM
123
4
Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 ALARM_ZN 4
[10]1011sssssss123sAsss4[13]
[10]602415[9]00030101[#s123|NBA4][13]
2.
OPENING
123
B
Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 OPENING
[10]1011sssssss123sOssss[13]
[10]AA4214[9]00040101[#s123|NOP][13]
3.
CLOSING 123 C Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 CLOSING
[10]1011sssssss123sCssss[13]
[10]F94B14[9]00050101[#s123|NCL][13]