Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
3.2.12 DSC 4-3 (Message Type d)
DSC4-3
Example
SIA Mode Description
<LF><CRC><d><sequence#><receiver#><line#>[#aaaa|XYY]<CR>
Table 59: DSC 4-3 (Message Type d) Byte Description
Title Description
LF Standard line feed character.
CRC Cyclical redundancy check number.
Message Type d
sequence# The message sequence number. The valid sequence number range is
0001 to 9999.
receiver# The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.
account# The communicator's account number has four digits.
X Event code number.
YY Zone number.
Figure 17: Message sent to printer
mm/ddshh:mmsLxxsDSGsACCTsaaaasEVENT=XYY
+++sACCsaaaaseeeeeeeesiisnnn
For lines that are grouped, Gxx appears instead of Lxx.