3.1.3 Ademco 4-2 Express (Message Type c)
4-2 Express
Example
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
h c r r l s s s s s s a a a a s E s s X Y t
Table 5: Message Type c (Ademco 4-2 Express) Byte Description
# Title Description
1 Header Character
(
)
Optional. Check with the computer automation software for
compatibility.
2 Message Type c
3-4 Receiver Number Receiver gateway number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6-11 Spaces Six spaces.
12-15 Account Number Account number, four digits.
16 Space One space.
17 E Event Code, “A” as the default.
18-19 Spaces Two spaces.
20-21 XY Event code and zone number.
22 Trailer Character Typically, this is HEX 14.