Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem
IIIa
.
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Modem4/ModemIIIa² Messages
Status: Fire Alarm / Waterflow
Sensor
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa WATER FLOW SENSOR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSFppppt
<header>[#aaaa|OriaaFApppp]
Status: Fire Missing
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE MISSING
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSZspppt
<header>[#aaaa|OriaFYppp]
Status: Fire Missing
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE MISSING
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSZppppt
<header>[#aaaa|OriaaFYpppp]
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSEspppt
<header>[#aaaa|OriaFSppp]
Status: Fire Supervision
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSEppppt
<header>[#aaaa|OriaaFSpppp]
Status: Fire Supervision /
Waterflow Sensor
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN
+++ACC aaaa WATER FLOW SENSOR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSEspppt
<header>[#aaaa|OriaFSppp]
Status: Fire Supervision /
Waterflow Sensor
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN
+++ACC aaaa WATER FLOW SENSOR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSEppppt
<header>[#aaaa|OriaaFSpppp]
Status: Fire Trouble
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSGspppt
<header>[#aaaa|OriaFTppp]
Status: Fire Trouble / Smoke
Detector
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE
+++ACC aaaa SMOKE DETECTOR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSGspppt
<header>[#aaaa|OriaFTppp]
Status: Fire Trouble / High Temp
Sensror
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE
+++ACC aaaa HIGH TEMPERATURE SENSOR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSGspppt
<header>[#aaaa|OriaFTppp]
Status: Fire Trouble / Waterflow
Sensor
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE
+++ACC aaaa WATER FLOW SENSOR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSGspppt
<header>[#aaaa|OriaFTppp]
Status: Fire Trouble
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSGppppt
<header>[#aaaa|OriaaFTpppp]
Status: Fire Trouble / Smoke
Detector
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE
+++ACC aaaa SMOKE DETECTOR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSGppppt
<header>[#aaaa|OriaaFTpppp]
Status: Fire Trouble / High Temp
Sensor
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE
+++ACC aaaa HIGH TEMPERATURE SENSOR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSGppppt
<header>[#aaaa|OriaaFTpppp]
Status: Fire Trouble / Waterflow
Sensor
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE
+++ACC aaaa WATER FLOW SENSOR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSGppppt
<header>[#aaaa|OriaaFTpppp]
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:GAS ALARM
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSAppppt
<header>[#aaaa|NriaaGApppp]
Message